• Vascular detector with bidirection waveform detecting the blood flow status TFT
  • Vascular detector with bidirection waveform detecting the blood flow status TFT
  • Vascular detector with bidirection waveform detecting the blood flow status TFT
  • Vascular detector with bidirection waveform detecting the blood flow status TFT
  • Vascular detector with bidirection waveform detecting the blood flow status TFT
  • Vascular detector with bidirection waveform detecting the blood flow status TFT
  • Vascular detector with bidirection waveform detecting the blood flow status TFT
  • Vascular detector with bidirection waveform detecting the blood flow status TFT
  • Vascular detector with bidirection waveform detecting the blood flow status TFT
  • Vascular detector with bidirection waveform detecting the blood flow status TFT
  • Vascular detector with bidirection waveform detecting the blood flow status TFT
  • Vascular detector with bidirection waveform detecting the blood flow status TFT
  • Vascular detector with bidirection waveform detecting the blood flow status TFT
  • Vascular detector with bidirection waveform detecting the blood flow status TFT
  • Vascular detector with bidirection waveform detecting the blood flow status TFT
  • Vascular detector with bidirection waveform detecting the blood flow status TFT
  • Vascular detector with bidirection waveform detecting the blood flow status TFT
  • Vascular detector with bidirection waveform detecting the blood flow status TFT
  • Vascular detector with bidirection waveform detecting the blood flow status TFT

Vascular detector with bidirection waveform detecting the blood flow status TFT

Model No.︰

BV-520T

Brand Name︰

Bestman

Country of Origin︰

China

Unit Price︰

-

Minimum Order︰

1 pc

Share on:

Product Description

Vascular detector with Bidirection waveform to detect the blood flow status

 

Features:

Detect the blood stream status of arterial/venous by 8.0MHz, the blood flow a verage velocity and the result of finger/toes and part of body's vein  anatomies operation.

  • Detect the blood flow average velocity, the result of fingers and toes and part of body's vein anatomies operation; It can be used to listen the tempera-mandibular joints (They become noisy when they start to brake because of the bite problems), assist doctor to check the conditions of the joints and predict the result of treatment.
  • Built-in ARM microprocessor & real-time displays blood flow velocity waveform;
  • store 50 curves;
  • High-speed USB port, can be connected directly to computer to analyze, store, and print the waveform.
  • Detect the pulse rate and show PR simultaneously
  • PPG probe for option

 

   Specifications:

  • Ultrasonic frequency: 8.0MHz±10%
  • Battery: 7.4V/900mAhrechargeable Lithium
  • Input voltage: DC 9V 1000mA
  • Doppler frequency: 100--7000Hz
  • Display: Color LCD 128×96 dots, display blood stream average velocity, PK, time, volume and battery
  • Working temperature: 10-40°C
  • Humidity: ≤80%
  • Atmospheric pressure: 86--106kPa

 

  • Packaging collocation:
    Single Unit Dimension: 26cm x 25cm x 12cm Gross Weight: 1.5kg
    6 pcs/carton Dimension: 49cm x 26cm x 33cm Gross Weight: 8.5kg
  • Normative collocation: charger, gel, operation manual, approval certification, warranty card
    Color LCD can display the waveform and the detecting result of the blood stream   

 



Packing︰ carton

Product Image